BMVGF - X-40 FOAM PART A, RT-5080-A
- MSDS: BMVGF
- Manufacturer: RESIN TECHNOLOGY CO
- Product Name: X-40 FOAM PART A, RT-5080-A
- National Stock Number: 8030-00N027857
Product Identification
Product ID:X-40 FOAM PART A, RT-5080-A
MSDS Date:08/01/1989
FSC:8030
NIIN:00N027857
Kit Part:Y
MSDS Number: BMVGF
Responsible Party
ONTARIO, CA 91761
US
Emergency Phone: 714-947-7224
Info Phone: 714-947-7224
Cage: RTECH
Contractor
Telephone: 714-947-7224
Cage: RTECH
Ingredients
SCBA. AIR PURIFYING (CARTRIDGE TYPE) RESPIRATORS
RTECS: 9999999ZZ
MAY NEED TO BE CLEANED BY SCRUBBERS/FILTERS TO REDUCE
RTECS: 9999999ZZ
HAVE EXCELLENT RESISTANCE. OTHER MATLS SUCH AS
RTECS: 9999999ZZ
TO "GUIDELINES FOR SELECTION OF CHEMICAL PROTECTIVE
RTECS: 9999999ZZ
SHOWER IN WORK AREA.
RTECS: 9999999ZZ
AIR RESPIRATOR W/FULL FCPIECE/AIR-SUPPLIED HOOD.
RTECS: 9999999ZZ
POLYMETHYLENE POLYPHENYL ISOCYANATE; (SIMILAR STRUCTURE
CAS: 9016-87-9
RTECS: TR0350000
Fraction By Weight: 50%
CHEST W/DFCLTY BRTHG. SYMPS MAY BE IMMED/DELAYED
RTECS: 9999999ZZ
CHRONIC EXPOSURES MAY RESULT IN PERM DECREASES IN
RTECS: 9999999ZZ
REMOVE VICTIM TO FRESH AIR. IF NOT BRTHG,
RTECS: 9999999ZZ
LABORED, GIVE OXYGEN. CONSULT MEDICAL PERSONNEL.
RTECS: 9999999ZZ
WATER(5-10% SODIUM CARBONATE MAY BE SUBSTITUTED
RTECS: 9999999ZZ
SOLN, USING 10 PARTS SOLN TO EACH PART SPILL & ALLOW
RTECS: 9999999ZZ
LEAVING INSOLUBLE POLYUREAS. FOR MAJOR SPILLS, CALL
RTECS: 9999999ZZ
DRUMS MUST BE DECONTAMD IN
RTECS: 9999999ZZ
ISOCYANATE VAPS. SPRAY/POUR 5-15 LITERS OF DECONTAM
RTECS: 9999999ZZ
LEAVE DRUM SOAKING UNSEALED FOR 48 HRS. POUR OUT
RTECS: 9999999ZZ
OTHERWISE DESTROY RINSED CONTAINER BEFORE DISPOSAL.
RTECS: 9999999ZZ
ISOCYANATES. THESE INDIVIDUALS SHOULD BE
RTECS: 9999999ZZ
FURTHER EXPOS. MED EXAM SHLD INCLUDE MED HISTORY,
RTECS: 9999999ZZ
ISOCYANIC ACID, METHYLENEDI-P-PHENYLENE ESTER; (MDI)
CAS: 101-68-8
RTECS: NQ9350000
Fraction By Weight: 50%
OSHA PEL 0.02 PPM, C
ACGIH TLV: 0.005 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:LD50: (ORAL,RAT) >10,000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST: SINGLE DOSE OF PROD IS
PRACTICALLY NONTOXIC BY INGEST. IRRIT OF MOUTH, PHARYNX, ESOPHAGUS
& STOMACH CAN DEVELOP FOLLOWING INGEST. EYE: MATL WILL PROBABLY
IRRIT HUMAN EYES FOLLOWING CONTACT. SK IN: NO IRRIT IS LIKELY
FOLLOWING SHORT CONTACT PERIODS W/HUMAN SKIN. SKIN SENSIT & IRRIT
MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: DEVEL AFTER RPTD/PRLNG CONT W/HUMAN
SKIN. PRLNG/RPTD SKIN CONT W/MDI CAN INDUCE DELAYED SKIN RXNS SEV
HOURS AFTER EXPOS. INHAL: VAPS/AEROSOLS CAN IRRIT EYES,NOSE & RESP
PASSAGES. SEVERE OVER EXP MAY LEAD TO PULM EDEMA. MDI CAN INDUCE
RESP SENSIT W/ASTHMA-LIKE SYMPS SIMILAR TO THOSE INDUCED BY (SUPP
DATA)
Medical Cond Aggravated by Exposure:PREVIOUSLY SENSITIZED INDIVIDUALS
OR TO INDIVIDUALS WITH EXISTING RESPIRATORY DISEASE, SUCH AS
CHRONIC BRONCHITIS, EMPHYSEMA, ASTHMA. SENSITIZED INDIVIDUALS SHLD
BE REMOVED FROM ANY FURTHER EXPOSURE.
First Aid
First Aid:SKIN: WASH MATL OFF OF SKIN W/PLENTY OF SOAP & WATER. IF
REDNESS, ITCHING, OR BURNING SENSIT DEVELS, GET MED ATTN. EYES:
IMMED FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. IF REDNESS,
ITCHING, BURNIN G SENSATION DEVEL, HAVE EYES EXAMINED &TREATED BY
MED PERS. INGEST: GIVE 1-2 GLASSES OF WATER TO DRINK. IF GI SYMPS
DEVEL, CONSULT MD. NEVER GIVE ANYTHING BY MOUTH TO UNCON PERS.
INHAL: (ING 5)
Fire Fighting
Flash Point Method:COC
Flash Point:425F,218C
Extinguishing Media:DRY CHEM, FOAM, CO*2, HALOGENATED AGENTS. IF H*2O
IS USED,USE VERY LGE QTYS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . THE REACTION BETWEEN WATER & HOT ISOCYANATE
MAY BE VIGOROUS.
Unusual Fire/Explosion Hazard:WATER CONTAMINATION WILL PRODUCE CO*2. DO
NOT RESEAL CONTAMINATED CONTAINERS AS PRESSURE BUILDUP MAY RUPTURE
THEM.
Accidental Release
Spill Release Procedures:WEAR SKIN, EYE, & RESP PROT DURING CLEANUP.
SOAK UP MATL W/ABSORB & SHOVEL INTO A CHEM WASTE CNTNR. COVER
CNTNR, BUT DO NOT SEAL & REMOVE FROM WORK AREA. PREPARE A DECONTAM
SOLUTION OF 0.2-5% LIQ DETE RGENT & 3-8% CONC AMMONIUM HYDROXIDE
IN(ING 7)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN TIGHTLY SEALED CNTNRS TO PROT
FROM ATMOS MOISTURE. STORE IN COOL AREA. PVNT SKIN/EYE CONTACT.
AVOID BRTHG VAPS/AEROSOLS. OBSERVE TLV LMTS.
Other Precautions:WORKERS SHLD SHOWER & CHANGE TO FRESH CLTHG AFTER
EACH SHIFT. SENSITIZED INDIVID SHLD NOT BE EXPOS TO PROD WHICH
CAUSED SENSIT. INDIVIDUALS W/EXISTING RESP DISEASE SUCH AS CHRONIC
BRONCHITIS, EMPHYSEM A/ASTHMA SHLD NOT BE EXPOS TO (ING 14)
Exposure Controls
Respiratory Protection:BECAUSE OF LOW VAP PRESS, VENT IS USUALLY
SUFFICIENT TO KEEP VAPS
EXCEED TLV, USE NIOSH/MSHA APPRVD POSITIVE PRESS SUPPLIED (ING 16)
Ventilation:USE LOC EXHST VENT TO KEEP AIRBORNE CONC
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEM WORK GOGS & FULL LNGTH FCSHLD
Other Protective Equipment:APRON-ARM COVERS-FULL BODY SUIT CONSTRUCTED
OF BUTYL/NITRILE RUBBER/SARANEX COATED TYVEK/SOME NEOPRENE GARMENTS
(ING 19)
Work Hygienic Practices:WASH CONTAMD CLOTHING BEFORE REWEARING.
Supplemental Safety and Health
BOIL PT:646F,341C(DECOMP). MATL TO AVOID:W/H*2O IS VERY SLOW <50C, BUT
ACCELS AT >TEMPS & IN PRESENCE OF ALKALIES/TERTIARY AMINES/METAL
CMPDS. SOME RXNS CAN BE VIOLENT. CNDTNS TO AVOID(POLY): OF CO*2
GAS MAY RUPTURE CLSD CNTNRS. EFTS OF OVEREXP: TDI (TOLUENE
DIISOCYANATE). SYMPS INCL CHRONIC COUGH, TIGHTNESS OF (ING 3)
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:646F,341C
Vapor Pres:<.0001@20C
Vapor Density:8.6
Spec Gravity:1.2
Solubility in Water:REACTS
Appearance and Odor:DARK BROWN, VISCOUS LIQUID WITH SLIGHT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
WILL REACT W/ANY MTLS CNTNG ACTIVE HYDROGENS, E.G., H*2O, ALCOHOL,
AMMONIA, AMINES, ALKALIES & ACIDS. THE RXN(SUPP DATA)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:COMBUST PRODS: CO*2, CO, NITROGEN
OXIDES, AMMONIA. TRACE AMOUNTS OF HYDROGEN CYANIDE.
Conditions to Avoid Polymerization:HIGH TEMPS IN PRESENCE OF ALKALIES,
TERTIARY AMINES, & METAL CMPDS WILL ACCELERATE POLYMERIZATION. POSS
EVOL (SUPP DATA)
Disposal
Waste Disposal Methods:SLOWLY STIR ISOCYANATE WASTE INTO DECOMTAM SOLN
USING 10 PARTS SOLN FOR EACH PART ISOCYANATE. LET STAND FOR 48 HRS,
ALLOWING EVOLVED CO*2 TO VENT AWAY. NEUT WASTE. NEITHER SOLID NOR
LIQ PORTION IS HAZ WASTE UNDER RCRA, 40 CFR 261. (ING 10)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.